Key Features: galvanic fuel cell featuring an extra water repellent head space, fits to Uwatec OxySpy, Mares EANx, Kiss Rebreather All characteristics are based on conditions at 25°C, 50% rel. H. and 1013 mBar
| Electrical Connector: |
3-pin Molex |
| Measurement Range: |
0 to 100 Vol.% |
| Nominal Sensor Life: |
more than 500 000 Vol.% h |
| Expected Operating Life: |
less than 3 years @ ambient air |
| Output Signal: |
9 to 12 mV @ dry ambient air |
| Response Time t90: |
less than 5 sec |
| Drift: |
less than 1% volume O2 / month @ air |
| Operating Temperature: |
0 to 45°C |
| Pressure Range: |
600 to 1750 hPa |
| Linearity Error: |
< 2% of full scale @ const. pressure, temperature |
| Zero Offset Voltage: |
less than 150 ?V in 100% N2, applied for 5 min |
| Influence of Humidity: |
-0.03 % rel. O2 reading per % r.H. |
| Recommended Load Resistor: |
more than 10 kOhms |
| Temperature Compensation: |
NTC |
| Interferences: |
none to He, H2 and CO |
|
Storage Conditions
|
|
| Temperature Range: |
recommended: 5 to 30°C |
| ? |
maximum: - 20 to 50°C |
| Ambient Pressure: |
600 to 1750 hPa |
| Humidity: |
up to 100% rel. H. |
| Shelf Life: |
less than 6 months |
| Weight: |
approximately 24 g |
| Material in contact with media: |
PA, PPS, PTFE, stainless steel |
| Warranty Period: |
12 months |
| Colour: |
white housing |
|